2019-6-19 直流屏的調試方法
1、首先檢查一次和二次回路接線是否正確-主要(yao)是查致命錯誤(wu),比如說弱點接口接上(shang)強電(dian)了,應該接入直流(liu)(liu)信(xin)號卻接入交(jiao)流(liu)(liu)信(xin)號了,還(huan)有(you)就是短路問題。 2、避(bi)免了以上(shang)的(de)原因,斷(duan)開所有(you)的(de)斷(duan)路器(qi)和保(bao)險,接通交(jiao)流(liu)(liu)電(dian)源,測試交(jiao)流(liu)(liu)雙(shuang)電(dian)源切換(huan)裝置是否工(gong)作正常(chang),雙(shuang)電(dian)...
2019-6-19 直流系統接地檢測方法分析及檢測裝置改進
發(fa)(fa)電(dian)(dian)(dian)廠、變(bian)電(dian)(dian)(dian)站(zhan)的(de)直流(liu)系統(tong)是一個(ge)獨立(li)的(de)電(dian)(dian)(dian)源,不受發(fa)(fa)電(dian)(dian)(dian)機、廠用(yong)電(dian)(dian)(dian)、站(zhan)用(yong)變(bian)以及系統(tong)運行方式改變(bian)的(de)影響,為(wei)電(dian)(dian)(dian)力系統(tong)的(de)控制(zhi)回(hui)路、信(xin)號回(hui)路、繼電(dian)(dian)(dian)保護、自動裝置及事故照明等提(ti)供可靠穩定的(de)不間斷電(dian)(dian)(dian)源,它還為(wei)斷路器的(de)分、合閘(zha)提(ti)供操作電(dian)(dian)(dian)源。因此直流(liu)電(dian)(dian)(dian)源系統(tong)對變(bian)...
2019-6-18 直流屏在作業中采取的預防措施
(1)進行(xing)直(zhi)流(liu)(liu)屏以及整流(liu)(liu)直(zhi)流(liu)(liu)電源裝置及其直(zhi)流(liu)(liu)回(hui)路的(de)清(qing)(qing)掃(sao)、檢(jian)查應由兩人(ren)進行(xing),其中(zhong)一(yi)人(ren)對進行(xing)工(gong)作(zuo)的(de)行(xing)為要(yao)加(jia)強監護,防止因失誤而傷人(ren)或損壞設備(bei)。 (2)在清(qing)(qing)掃(sao)、檢(jian)查中(zhong),如需對運行(xing)中(zhong)的(de)部分元件(jian)作(zuo)進一(yi)步檢(jian)查或需處理缺陷,工(gong)作(zuo)時需遵(zun)守《...
2019-6-17 閥控式密封鉛酸蓄電池的使用優勢分析
可以使(shi)用(yong)(yong)(yong)15年以上,使(shi)用(yong)(yong)(yong)期間不用(yong)(yong)(yong)經常加水(shui),電(dian)池(chi)的密封結構(gou)杜絕了漏酸的產生閥控式密封鉛酸蓄電(dian)池(chi),達到了安(an)全和環(huan)保的目的,廣泛應(ying)用(yong)(yong)(yong)于(yu)通信系統、電(dian)力系統、UPS備用(yong)(yong)(yong)電(dian)源(yuan)、水(shui)電(dian)站(zhan)、火電(dian)廠、國防通信、安(an)全應(ying)急照明報警疏散系統等。 閥控...
2019-6-17 全自動充電機保證安全充電的關鍵
1,全自動充(chong)(chong)電(dian)(dian)機輸出有正、負點(dian),不要反轉(zhuan)。紅(hong)線連接電(dian)(dian)池充(chong)(chong)電(dian)(dian)器連接電(dian)(dian)池負極,綠色(se)線。 2,紅(hong)色(se)的(de),綠色(se)的(de)充(chong)(chong)電(dian)(dian)器輸出不能短(duan)路(即連接)。 3,充(chong)(chong)電(dian)(dian),220v-230v電(dian)(dian)壓范(fan)圍之間。 4,充(chong)(chong)電(dian)(dian)電(dian)(dian)池可以不缺乏液體...
2019-6-14 智能充電機不間斷電源常見故障現象原因分析?
在日(ri)常處理Smart-智能(neng)(neng)充(chong)(chong)電(dian)機(ji)報(bao)修(xiu)申(shen)請(qing)的(de)(de)過(guo)程中,我們發現有許(xu)多智能(neng)(neng)充(chong)(chong)電(dian)機(ji)的(de)(de)故(gu)障現象是由(you)于電(dian)池、市電(dian)、使(shi)用(yong)(yong)環境和使(shi)用(yong)(yong)方法等因(yin)素造(zao)成的(de)(de),有相當一部(bu)分(fen)智能(neng)(neng)充(chong)(chong)電(dian)機(ji)本身(shen)并沒(mei)有出現故(gu)障。如果能(neng)(neng)將這些(xie)因(yin)素找出來,判斷出并非是由(you)于智能(neng)(neng)充(chong)(chong)電(dian)機(ji)引起的(de)(de)故(gu)障現象...
2019-6-14 處理蓄電池充電機突然停電的方法
處(chu)理蓄(xu)(xu)(xu)(xu)電(dian)(dian)(dian)(dian)(dian)池充(chong)(chong)(chong)電(dian)(dian)(dian)(dian)(dian)機(ji)突(tu)然(ran)停電(dian)(dian)(dian)(dian)(dian)的(de)(de)方法 當蓄(xu)(xu)(xu)(xu)電(dian)(dian)(dian)(dian)(dian)池充(chong)(chong)(chong)足(zu)(zu)電(dian)(dian)(dian)(dian)(dian)后,充(chong)(chong)(chong)電(dian)(dian)(dian)(dian)(dian)機(ji)必須適時(shi)地切斷充(chong)(chong)(chong)電(dian)(dian)(dian)(dian)(dian)電(dian)(dian)(dian)(dian)(dian)流,否則蓄(xu)(xu)(xu)(xu)電(dian)(dian)(dian)(dian)(dian)池將出現大量出氣、失水和溫升(sheng)等過(guo)充(chong)(chong)(chong)反應,直接危(wei)及(ji)蓄(xu)(xu)(xu)(xu)電(dian)(dian)(dian)(dian)(dian)池的(de)(de)使用壽命。因此(ci),必須隨時(shi)監(jian)測(ce)蓄(xu)(xu)(xu)(xu)電(dian)(dian)(dian)(dian)(dian)池的(de)(de)充(chong)(chong)(chong)電(dian)(dian)(dian)(dian)(dian)狀況,保證電(dian)(dian)(dian)(dian)(dian)池充(chong)(chong)(chong)足(zu)(zu)電(dian)(dian)(dian)(dian)(dian)而又不過(guo)充(chong)(chong)(chong)電(dian)(dian)(dian)(dian)(dian)。主要的(de)(de)停充(chong)(chong)(chong)控...
2019-6-13 大功率蓄電池充電機有什么特點及常見故障
大功率蓄電池(chi)充(chong)電機采(cai)用了功能(neng)完善的(de)電源IC,并由數字(zi)邏輯電路(lu)進行(xing)實行(xing)采(cai)樣控制,自動檢測所(suo)充(chong)蓄電池(chi)的(de)狀態。 大功率蓄電池(chi)充(chong)電機主要(yao)功能(neng): 1. 采(cai)用“恒(heng)(heng)流(liu)-恒(heng)(heng)壓限流(liu)-恒(heng)(heng)壓浮充(chong)”充(chong)電模式,要(yao)求達到全自動工(gong)作狀態,適合無(wu)人值守的(de)工(gong)作場合。 ...